Endobronchial Ultrasound (EBUS) scopes

Fujifilm EB-710US balloon-less endobronchial ultrasound (EBUS) scope with 180o up angulation.

Advancing pulmonary care with balloon-less EBUS scope technology

As a trusted partner to pulmonologists, Fujifilm is committed to bringing innovative, practical solutions to the US market. The EB-710US reflects this commitment.

Designed to reduce costs, shorten preparation time, and eliminate balloon-related infection risk, its innovative features also aid in expanding capabilities in diagnosis and staging.

With its 180° acute angulation, thin diameter, and novel balloon-less design, the EB-710US facilitates navigation of challenging bronchial angles and complex branching to reach targets in peripheral regions typically not accessible with EBUS.

Complementing its outstanding maneuverability, the EB-710US provides a wide 120° field of view, intuitive 10° forward-facing view and Fujifilm’s cutting-edge imaging technology.

In published reports, physicians document successfully accessing challenging mediastinal and peripheral targets without a balloon.1-3

Find out how the EB-710US can help advance your interventional pulmonology practice.

Contact Us

 

The EB-710US delivers

  • Impressive angulation—180° up and 90° down
  • An innovative, ergonomic 10° forward-facing view for precise navigation, enhanced needle visibility, and accurate puncture capabilities
  • A slim 6.4mm distal end and 5.9mm insertion tube
  • A shortened transducer to help improve mucosal contact and optimize ultrasound performance during procedures
  • CMOS imaging for brilliant image transmission

EB-710US Highlights

Fujifilm EB-710US endobronchial ultrasound (EBUS) bronchoscope
Balloon-less Advantage
Optimal Visualization
10° Forward-Facing View
Designed for Flexibility
High-performance Imaging
Fujifilm EB-710US endobronchial ultrasound (EBUS) bronchoscope

Balloon-less Advantage

  • Eliminates balloon-related infection risks
  • No adverse events related to ultrasound balloon use
  • Streamlines procedural setup—no balloon to attach or air bubbles to purge
  • Compatible with STERRAD® and EOG sterilization

STERRAD Systems provided by Advanced Sterilization Products, Inc.

Optimal Visualization

Positioning of the objective lens, CMOS image sensor, and instrument channel provide continuous, unobstructed view of the needle for accurate puncturing action.

10° Forward-Facing View

Innovative, ergonomic 10° forward-facing view for precise navigation. Advances similarly to a standard bronchoscope facilitating entry into the trachea or esophagus.3

Designed for Flexibility

  • Short and thin distal end aids insertion3
  • 2.2mm working channel allows smooth device passage and reliable sampling performance
  • Fits 19G to 25G needles to accommodate your approach

High-performance Imaging

  • Fujifilm’s latest ultrasound transducer delivers enhanced resolution and deep penetration producing a clear, detailed ultrasound image
  • CMOS technology ensures a high-resolution, smooth-moving image with reduced blurring

EB-710US Features & Specifications

Feature Specification
Viewing Direction 10° Forward
Field of View 120°
Observation Range 2-50mm
Image Sensor CMOS
Distal End Diameter  6.4mm
Insertion Tube Diameter  5.9mm
Working Channel Diameter 2.2mm
Angulation Up/Down 180o/90o
Working Length 610mm
Sterilization STERRAD/EOG

 

EB-530US

Convex EBUS scope

Designed for precise diagnosis and staging in pulmonary procedures, the EB-530US offers reliable control and maneuverability. With enhanced distal angulation and a slim design, this bronchoscope represents innovation you can count on for a range of procedures.

Like the EB-710US, the EB-530US offers an intuitive 10o forward-facing view, 120o wide viewing angle, and ample flexion, allowing it to substitute for a conventional bronchoscope for airway inspection prior to EBUS.4

As noted in the Journal of Thoracic Disease:

“It [EB-530US] obviates the need for airway inspection using a conventional bronchoscopy and is associated with decreased procedure times/procedural costs.”4

EB-530US highlights:

  • Optimized needle guide facilitates precise puncture action
  • With the 10° forward-facing view, the EB-530US advances similarly to a standard bronchoscope4
  • High-resolution Super CCD imaging

Like the EB-710US, the EB-530US offers a continuous unobstructed view of the needle to help ensure accurate puncture alignment.

EB-530US supports a balloon option for advanced stability.

EB-530US Features & Specifications

Feature Specification
Viewing Direction 10° Forward
Field of View 120°
Observation Range 3-100mm
Image Sensor CCD
Distal End Diameter  6.7mm
Insertion Tube Diameter  6.3mm
Working Channel Diameter 2.0mm
Angulation Up/Down 130o/90o
Working Length 610mm
Sterilization EOG

 

 

References

  1. Watanabe H, Oki M, Shinohara Y, Toshihiro O, Imaeda Y, Iwakoshi A. EBUS-TBNA for lung cancer in the apical segment of the right upper lobe using a new EBUS scope. Respir Med Case Rep. 2026;59:102368. doi:10.1016/j.rmcr.2026.102368
  2. Kapp C, Thiboutot J, Wang, D, et al. Quality of lymph node visualization using a novel slim linear EBUS bronchoscope versus a conventional linear EBUS bronchoscope: a crossover, single-blinded cadaveric study. CHEST Pulmonary. 2025;100202. doi.org/10.1016/j.chpulm.2025.100202
  3. Takigawa Y, Sato K, Matsuoka S, et al. Usefulness of novel balloon-less convex probe bronchoscope for diagnosing and staging of lung cancer via EBUS-TBNA and EUS-B-FNA. Respirol Case Rep. 2026;14(2):e70506. doi:10.1002/rcr2.70506
  4. Yarmus L, Akulian J, Ortiz R, et al. A randomized controlled trial evaluating airway inspection effectiveness during endobronchial ultrasound bronchoscopy. J Thorac Dis. 2015;7(10):1825-1832. doi:10.3978/j.issn.2072-1439.2015.09.42

 

 

 

 

Call to action icon

Get To Know Us Better

Let us help you find the right product or service that will suit your needs.

Get In Touch